NIDEK


ProductsOphthalmic EquipmentOptometric & Lens Edging EquipmentLasers for DermatologyCoating


About NIDEK


Optical Illusions

Eye & Health Care
HomeEventsPress ReleasesDistributor SearchContact UsSite Map

Site Search

Surgical CO2 Laser System
COL-1040

COL-1040 (UniPulse 1040)

SPEED & PRECISION

  • High Frequency Scanner
    300Hz - the fastest among available.

  • 1.0 mm Spot Size with Adjustable Overlap for hyper-fine resolution, uniform coverage.

  • Ergonomic Handpiece for maximum control and comfort.

  • Integrated purge/suction ports maintain clear surgical field for continuous laser application.

  • Detachable Nose Piece that is reusable and autoclavable.

QUALITYCooling Handpiece

  • UniPulseTM Technology provides uniform and rapid CO2 laser energy distribution.

  • Leading Edge Optical Design sets a new standard for beam quality.

  • "Flat" Beam Profile provides uniform energy distribution to tissue/no tissue "hot" spots.

  • Optimized Variable Pulse Width for effective ablation and tightening with minimal thermal diffusion.

  • Optimized Pulse Shape for preferred energy distribution to tissue.

VERSATILITY
The COL-1040 (UniPulse 1040) has a wide range of accessories engineered for precise beam coincidence and optimal results in a wide range of surgical applications.

AccessoriesAccessories

SURGICAL APPLICATIONS:

  • General Surgery
  • Aesthetic Surgery
  • ENT
  • Gynecologic Surgery

AESTHETIC CASE STUDIES:

Case Study 1
High energy densities and FastScanTM scanner make the UniPulseTM CO2 laser an excellent option for skin resurfacing.

Case Study 1Case Study 1
Skin Resurfacing

Sex:

Female

Power:

16W (Periorbital), 18W (Perioral / Full Face)

Density:

10%
2 passes

(Photographs courtesy of Maureen Muecke, MD, Birmingham, AL, USA)


Case Study 2

Case Study 2Clinical findings immediately after the short-pulsed CO2 laser irradiation, using the square pattern.

(H. Nakaoka, MD, Ehime University, School of Medicine, JAPAN)


Case Study 3

Case Study 3Histological findings after exposed to power 20W (HE, x 100). Coagulation and/or necrosis is seen only through epidermis to the papillary layer of dermis.

(H. Nakaoka, MD, Ehime University, School of Medicine, JAPAN)

Contact Us

Top of Page

NOTE:

The product may not be available in certain countries where it has not received marketing/clinical approval. Specifications and design are subject to change without notice.

Surgical Applications & Case Studies

The Art of Eye CareNIDEK CO., LTD.

You can also reach us via e-mail info@nidek.co.jp | Privacy Policy | Legal Notes